The EtherNet/IP Client/Server Network Interface Module allows PLC processors to interface with EtherNet/IP protocol (Explicit Messaging) compatible devices and hosts. The MVI71-DFNT module provides a serial pass-thru channel 0 service for remote Ethernet programming and troubleshooting.

The MVI71-DFNT module is a single slot solution that provides a powerful connection between Rockwell Automations PLC processor and EtherNet/IP (DF1 for Ethernet) network applications.

The module can send read or write commands to remote devices on the EtherNet/IP network. The MVI71-DFNT also has 20 servers that allows the module to receive commands from remote devices. The MVI71-DFNT Pass-Through server allows the user to edit and transfer the PLC ladder logic using an Ethernet connection. Up to 100 commands can be configured by the user.

List of Rockwell Automation material that support EPIC:

MicroLogix 1100/1400/ANY via 1761-NET-ENI

CompactLogix 1768-L43/L45 via 1768-ENBT

CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI

Single Slot – 1771 backplane compatible

The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module

Ladder Logic is used for data transfer between module and processor. Sample ladder file include.

Configuration data obtained from configuration text file downloaded to module. Sample configuration file included.

Single Slot – 1771 backplane compatible

The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module

Ladder Logic is used for data transfer between module and processor. Sample ladder file included.

EtherNet/IP (Explicit Messaging) Compatible Devices

Rockwell Automation equipment that supports EPIC:

MicroLogix 1100/1400/ANY via 1761-NET-ENI

CompactLogix 1768-L43/L45 via 1768-ENBT

ControlLogix 1756-ENET/ENBT/EN2T/EN2TR

PLC processor in-chassis EtherNet/IP bridge to optimize data throughput while communicating with HMI or SCADA and other control platforms without losing valuable process control bandwidth

Support of up to 4000 PLC registers user data files

10/100 MB Ethernet compatible interface

Configurable parameters for the client include:

A minimum response delay of 0 to 65535 mSec

A response timeout of 1 to 65535 mSec

Status data available in ladder logic

Support for PLC processor programming over Ethernet using a TCP/IP service and a serial port on the module connected to channel 0 of the processor. The modules third port emulates Channel 0 of the processor to pass through messages from the port to the processor

Supports EtherNet/IP explicit, connected, and unconnected class messaging

Twenty independent server connections permit remote clients to interact with all data contained in the module

Data can be derived from other clients on the network, through the client on the module, or from the PLC processor

Actively issues connected, explicit messages to other nodes on the network

Supports 100 user-defined commands from a single client

Allows command control from ladder logic

Permits remote programming of the PLC processor on the Ethernet network via a pass-through

TCP/IP service and a serial communication port (pass-through port) on the module

The third port on the module can emulate the Channel 0 port on the PLC, This allows a DF1 master device attached to the emulated (Channel 0) port to monitor and control data in the PLC.

Serial activity and error LED status

Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991

Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration